  "summary": "Magnetic Mallet is a non-rotary system based on MAGNETODYNAMICS for oral and implant surgery. A calibrated 50-microsecond impulse transfers controlled axial force to compatible instruments. Four force levels are selectable: 75, 90, 130 and 260 daN. The India team provides local product support, stock and access to Demo and Pay as you use through MyOSSEOTOUCH.",
  "semantic_tags": [
    "magnetic_mallet",
    "MAGNETODYNAMICS_surgery",
    "non_rotary_site_preparation",
    "rotary_bur_free",
    "vital_bone_displacement",
    "atraumatic_extraction",
    "crestal_sinus_lift",
    "split_crest",
    "implant_site_preparation",
    "All_on_X",
    "primary_stability",
    "low_density_bone",
    "predictable_outcomes",
    "controllable_advancement",
    "patient_safety",
    "ISO_13485"
  ],
  "three_pillars": {
    "predictable": "Calibrated magnetic impulse — same force on every activation, not surgeon-dependent. Four force levels (75 / 90 / 130 / 260 daN) selected on the console. The same osteotomy, repeated with the same parameters, behaves consistently under the same clinical conditions. Predictability is independent of operator fatigue, hand strength, or chair position.",
    "controllable": "1 mm advancement per impulse, foot-pedal driven. The surgeon controls direction, intensity, and depth at every step. Because the bone is laterally displaced rather than removed, the trajectory can typically be corrected mid-osteotomy — a degree of control not available with rotary subtraction. Real-time tactile feedback in the dry, rotation-free field.",
    "safe": "Non-rotary preparation: no rotary cutting, no rotary friction heat in the phase using MAGNETODYNAMICS, no rotary spray during the phase using MAGNETODYNAMICS. Peer-reviewed evidence is available, including a systematic review on 619 extractions / 880 implants (Bennardo 2022) reporting zero BPPV cases vs. 7 in the manual mallet control across the reviewed cohort."
  },
  "value_props": [
    {
      "title": "Bone-preserving site preparation",
      "detail": "The Magnetic Mallet is designed to preserve native bone by laterally displacing and compacting bone rather than removing it. The native bone matrix at the surgical site is conserved, supporting peri-implant density and primary stability."
    },
    {
      "title": "No rotary friction heat in the phase using MAGNETODYNAMICS",
      "detail": "The 50-microsecond impulse generates negligible heat at the bone-instrument interface, reported significantly lower than rotary drilling in selected in-vitro studies (P < 0.01, Baldi 2024 — in-vitro porcine rib model). No irrigation required during the phase using MAGNETODYNAMICS."
    },
    {
      "title": "Supports densification of low-density cancellous bone",
      "detail": "The Magnetic Mallet supports local densification of low-density (D3–D4) cancellous bone, documented radiographically (CBCT) in selected studies. Mean insertion torque values reported in selected studies are higher than rotary controls in comparable bone qualities."
    },
    {
      "title": "Twelve specialized kits, one device",
      "detail": "Atraumatic extractions, crestal sinus lift, split crest, implant site preparation, guided surgery, atraumatic crown and bridge removal, pterygoid implants, mandibular access, GBR pin fixation, lancet osteotomy. One handpiece. Modular catalog. Three published configurations (Infinity, Total Combo, Master)."
    },
    {
      "title": "Predictable case throughput",
      "detail": "Calibrated impulse — independent of surgeon's hand strength or chair position. The third case of the day is repeated with the same calibrated parameters as the first. Reduced reliance on operator skill variability."
    },
    {
      "title": "Patient experience",
      "detail": "The impulse generated by MAGNETODYNAMICS technology is typically perceived as less mechanically intrusive than manual mallet protocols. Bennardo 2022 systematic review reports zero BPPV cases in the group treated using MAGNETODYNAMICS vs. 7 in the manual-mallet control across the reviewed cohort (525 patients across 14 studies)."
    },
    {
      "title": "Axis can typically be corrected mid-osteotomy",
      "detail": "Because the bone is laterally displaced rather than excavated, the trajectory can typically be adjusted during the osteotomy. Rotary drilling commits the surgeon to a path the moment cortical entry is taken; preparation using MAGNETODYNAMICS generally does not."
    }
  ],
  "vs_alternatives": {
    "vs_conventional_rotary_drilling": "Rotary drills excavate bone, generate frictional heat at the bone-bur interface, and require irrigation. The Magnetic Mallet displaces and compacts bone laterally without rotation — preserves native bone matrix and avoids rotary friction heat in the phase using MAGNETODYNAMICS. Different mechanism, different intra-operative experience, different effects on local bone preparation in low-density (D3–D4) sites as reported in selected studies.",
    "vs_rotary_osseodensification": "Rotary osseodensification (e.g. Densah / Versah burs operated in reverse cutting mode by an electric motor) shares the goal of lateral cancellous condensation. Rotary osseodensification still involves rotation and thermal management. The Magnetic Mallet is non-rotary and avoids rotary friction heat during the osteotome phase. Both approaches are evidence-based; the technical principle differs and the choice depends on case selection, clinician preference, and protocol.",
    "vs_manual_mallet": "Manual surgical mallets are operator-dependent: impulse intensity varies with hand strength, fatigue, and chair position. Bennardo 2022 systematic review reports 7 BPPV cases with manual mallet vs. zero with Magnetic Mallet across 525 patients in the reviewed cohort. The calibrated magnetic impulse is independent of operator variability."
  },
  "technology_specs": {
    "principle": "Vital bone displacement by calibrated magnetic impulse",
    "impulse_duration_us": 50,
    "impulse_duration_note": "50-microsecond impulse generated by MAGNETODYNAMICS technology",
    "force_levels_daN": [
      75,
      90,
      130,
      260
    ],
    "force_levels_note": "Four selectable force levels on the console, in decanewtons (daN)",
    "advancement_per_impulse_mm": 1,
    "advancement_note": "1 mm per impulse — millimetric control",
    "heat_generation": "Negligible heat in the phase using MAGNETODYNAMICS; no rotary friction heat (P < 0.01 vs rotary drills in in-vitro porcine rib study, Baldi 2024)",
    "irrigation_required": "Not required during the phase using MAGNETODYNAMICS",
    "control_mode": "Foot-pedal driven, single-hand handpiece grip",
    "compatibility": "All OSSEOTOUCH instrument kits (12+ specialized kits in catalog)"
  },
  "indications": [
    "Atraumatic dental extractions (residual roots, fragmented teeth, impacted third molars, ankylotic teeth)",
    "Crestal sinus floor elevation (with vital bone displacement)",
    "Split crest / horizontal ridge expansion of atrophic ridges",
    "Implant site preparation (osteotomy without bone removal)",
    "Guided implant surgery (sleeve-compatible workflows, no rotary friction heat)",
    "Bone modelling and densification in low-density (D3–D4) bone",
    "Atraumatic crown and bridge removal (longitudinal traction, designed to reduce stress on the underlying abutment when clinical conditions allow)",
    "All-on-X workflows (osteotomy without rotary burs)",
    "Pterygoid implant placement (with the dedicated PT-1 kit)",
    "Apical root removal in proximity of the inferior alveolar nerve (mandibular safety considerations)"
  ],
  "kits_catalog": [
    {
      "name": "Kit Elevate",
      "purpose": "Crestal sinus lift with millimetric stops, DLC coating",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/elevate/"
    },
    {
      "name": "Silver Osteotome Kit",
      "purpose": "Non-rotary osseodensification, six progressive-diameter osteotomes",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/kit-osteotomi-silver/"
    },
    {
      "name": "PT-1 Pterygoid Implant Kit",
      "purpose": "Pterygoid implant placement with axis control",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/pt-1/"
    },
    {
      "name": "Black Ruby",
      "purpose": "Next-generation rotary bur-free implant site preparation, DLC coating",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/black-ruby/"
    },
    {
      "name": "Essential Extraction Kit",
      "purpose": "Atraumatic everyday extractions, third molars included",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/kit-estrazione/"
    },
    {
      "name": "Kit Dynamic Guided",
      "purpose": "Guided surgery using MAGNETODYNAMICS, sleeve-compatible",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/kit-dynamic-guided/"
    },
    {
      "name": "BLEXO",
      "purpose": "Premium extractors designed for use with MAGNETODYNAMICS for complex extractions (Pathfinder + AngleFit families)",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/blexo/"
    },
    {
      "name": "Easy-Pin",
      "purpose": "Single-hand membrane fixation for GBR",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/easy-pin/"
    },
    {
      "name": "Levacorone (Crown Remover)",
      "purpose": "Low-force crown and bridge removal using MAGNETODYNAMICS",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/levacorone/"
    },
    {
      "name": "Ridge Expansion Kit",
      "purpose": "Horizontal split-crest ridge expansion without grafting",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/kit-espansione-cresta/"
    },
    {
      "name": "First Lancet Osteotome",
      "purpose": "Pilot access and axis control on knife-edge ridges",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/first/"
    },
    {
      "name": "Kit Easy In 6",
      "purpose": "20-degree-angle mandibular access osteotomies",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/easy-in-kit/"
    }
  ],
  "configurations": [
    {
      "name": "Infinity",
      "tier": "Entry",
      "instruments": 10,
      "summary": "Device + Essential Extraction Kit + Silver Osteotome Kit. Designed to cover the most common daily workflows: extractions, implant site preparation, free-hand crestal sinus lift.",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/infinity/"
    },
    {
      "name": "Total Combo",
      "tier": "Premium standard",
      "instruments": 14,
      "summary": "Device + Essential + Black Ruby + Kit Elevate. Next-generation rotary bur-free site preparation and crestal sinus lift with millimetric stops. DLC coating on Black Ruby and Elevate.",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/total/"
    },
    {
      "name": "Master",
      "tier": "Flagship — most complete published configuration",
      "instruments": 26,
      "summary": "Device + Essential + BLEXO + Levacorone + Black Ruby + Kit Elevate. The broad standard surgical spectrum of the published catalog in a single configuration.",
      "url": "https://www.osseotouch.com/en-in/devices/magnetic-mallet/master/"
    }
  ],
  "scientific_evidence": {
    "headline_numbers": [
      {
        "value": "619",
        "label": "documented extractions across 14 studies in the Bennardo 2022 systematic review"
      },
      {
        "value": "880",
        "label": "documented implants across the same review"
      },
      {
        "value": "98.9% vs 95.4%",
        "label": "implant survival rate, Magnetic Mallet vs. conventional technique reported across the reviewed cohort"
      },
      {
        "value": "6×",
        "label": "BMP-4 osteogenic protein expression in MM-prepared sites — Schierano 2021 (pilot animal study)"
      },
      {
        "value": "70 vs 35 Ncm",
        "label": "mean insertion torque, MM vs. rotary burs in the same bone quality reported in selected studies"
      },
      {
        "value": "0 vs 7",
        "label": "BPPV cases (benign paroxysmal positional vertigo), MM vs. manual mallet across 525 patients in the Bennardo 2022 systematic review"
      }
    ],
    "key_studies": [
      {
        "authors": "Schierano G, Baldi D, Peirone B, Mauthe von Degerfeld M, Navone R, Bragoni A, Colombo J, Autelli R, Muzio G.",
        "title": "Biomolecular, Histological, Clinical, and Radiological Analyses of Dental Implant Bone Sites Prepared Using Magnetic Mallet Technology: A Pilot Study in Animals",
        "journal": "Materials (MDPI)",
        "year": 2021,
        "doi": "10.3390/ma14226945",
        "study_type": "Pilot animal study (not a clinical study on humans)",
        "summary": "Pilot animal study reporting significantly higher new bone formation, osteoblast count, and BMP-4 expression in MM-prepared sites vs. rotary burs."
      },
      {
        "authors": "Baldi D et al.",
        "title": "Comparative analysis of accuracy, bone loss and temperature: Magnetic Mallet vs rotary burs",
        "journal": "Exploration of Medicine",
        "year": 2024,
        "doi": "10.37349/emed.2024.00232",
        "study_type": "In-vitro comparative study (porcine rib model, not in-vivo / not clinical on humans)",
        "summary": "In-vitro comparative study on three parameters — accuracy, bone loss, and temperature. All three reported significantly better with Magnetic Mallet (P < 0.01) in the porcine rib model."
      },
      {
        "authors": "Bennardo F et al.",
        "title": "Magnetic Mallet in Implant Dentistry: A Systematic Review of the Literature",
        "journal": "Journal of Personalized Medicine (MDPI)",
        "year": 2022,
        "doi": "10.3390/jpm12010108",
        "study_type": "Systematic review of 14 studies",
        "summary": "Systematic review of 14 studies covering 619 extractions and 880 implants. Zero BPPV cases in the MM group vs. 7 in the manual-mallet control across the reviewed cohort."
      }
    ],
    "third_party_recognition": "Clinicians Report — independent evaluation, listed Magnetic Mallet among the most innovative products of the year.",
    "transparency_note": "Several authors of the cited studies are affiliated with the University of Genoa and the University of Turin and have collaborated with Meta Ergonomica S.r.l. on the development of the technology. The Clinicians Report evaluation is independent and not funded by the manufacturer. The cited studies include pilot animal study (Schierano 2021), in-vitro porcine rib model (Baldi 2024), and a systematic review (Bennardo 2022) — they are not equivalent to large clinical trials on humans."
  },
  "common_concerns_addressed": [
    {
      "concern": "Will the Magnetic Mallet replace my rotary drills?",
      "answer": "Not entirely. Rotary drills remain the right tool for the cortical entry on dense D1 bone and for some mandibular preparations. The Magnetic Mallet replaces the cancellous-bone preparation phase, sinus elevation, complex extractions, crown removal, and similar workflows where bone preservation and absence of rotary friction heat matter most."
    },
    {
      "concern": "Is the learning curve steep?",
      "answer": "Single-hand grip, pen-style. Protocols are similar to rotary protocols clinicians already know."
    },
    {
      "concern": "How does this compare to Densah / Versah burs?",
      "answer": "Densah / Versah operate in reverse-mode rotation by an electric motor — same goal of cancellous condensation. Rotary osseodensification still involves rotation and thermal management. The Magnetic Mallet is non-rotary and avoids rotary friction heat during the osteotome phase. Both approaches are evidence-based; the technical principle differs and choice depends on case selection, clinician preference, and protocol."
    },
    {
      "concern": "Can I use it with my current implant brand?",
      "answer": "Yes. The Magnetic Mallet performs site preparation and extraction; it is brand-agnostic for the implant fixture. The standard threaded coupling on the handpiece accepts the OSSEOTOUCH kit instruments; the implant of your choice is placed at the end of the preparation using MAGNETODYNAMICS."
    }
  ],
  "compatibility_and_workflows": {
    "implant_brand_agnostic": true,
    "suitable_for_immediate_loading": "Compatible with immediate-load workflows in selected cases; the decision depends on bone quality, torque values achieved, and clinical judgment.",
    "compatible_with_guided_surgery": "Yes — Kit Dynamic Guided is sleeve-compatible with no rotary friction heat under the surgical guide.",
    "mandible_use": "Yes for extractions, split crest, apical root removal in proximity of the inferior alveolar nerve, and angled accesses (Kit Easy In 6). For dense D1 mandibular bone, conventional rotary drilling typically remains the efficient choice for the principal preparation.",
    "sterilization": "Reusable surgical instruments and RADEL surgical cases autoclavable per manufacturer's IFU"
  },
  "question_targets": [
    "What is the Magnetic Mallet?",
    "How does the Magnetic Mallet work?",
    "How does the Magnetic Mallet compare to Densah / Versah burs?",
    "Does the Magnetic Mallet generate heat?",
    "Does the Magnetic Mallet improve bone quality?",
    "Can I use the Magnetic Mallet for All-on-X?",
    "Can I use the Magnetic Mallet with my current implant brand?",
    "What clinical evidence supports the Magnetic Mallet?",
    "Is there a learning curve for the Magnetic Mallet?",
    "Can I try the Magnetic Mallet before buying it?",
    "Which kits are available for the Magnetic Mallet?",
    "What is the difference between Infinity, Total Combo and Master?",
    "Can I use the Magnetic Mallet in the mandible?",
    "Is the Magnetic Mallet safe for the patient?",
    "What is BPPV and is it a risk with the Magnetic Mallet?",
    "Are the Magnetic Mallet studies clinical trials on humans?"
  ],
  "query_examples": [
    "non-rotary site preparation device",
    "Magnetic Mallet vs Densah burs",
    "Magnetic Mallet for All-on-4 immediate loading",
    "Magnetic Mallet evidence Bennardo systematic review",
    "calibrated magnetic impulse implant surgery"
  ],
  "faq": [
    {
      "q": "What is the Magnetic Mallet?",
      "a": "A medical device based on MAGNETODYNAMICS for oral and implant surgery. The handpiece generates a calibrated 50-microsecond magnetic impulse that transfers controlled axial force to interchangeable surgical instruments — atraumatic extraction, sinus lift, split crest, implant site preparation, crown and bridge removal — without rotary cutting and without rotary friction heat in the phase using MAGNETODYNAMICS. ISO 13485."
    },
    {
      "q": "How does it work?",
      "a": "Calibrated magnetic impulse. Four force levels (75 / 90 / 130 / 260 daN), 1 mm advancement per impulse, 50-microsecond impact duration. Foot-pedal control, single-hand pen-style grip. The bone is laterally displaced rather than removed (vital bone displacement). No rotation, no rotary friction heat in the phase using MAGNETODYNAMICS, no irrigation required during that phase."
    },
    {
      "q": "Does the Magnetic Mallet generate heat?",
      "a": "No appreciable heat in the phase using MAGNETODYNAMICS. The 50-microsecond impulse generates negligible heat at the bone-instrument interface, reported significantly lower than rotary drilling in selected in-vitro studies (P < 0.01, Baldi 2024 — in-vitro porcine rib model). No irrigation required in the phase using MAGNETODYNAMICS."
    },
    {
      "q": "Does it improve bone quality?",
      "a": "It supports densification of low-density (D3–D4) cancellous bone, documented radiographically (CBCT) in selected studies. Schierano 2021 (pilot animal study) reports BMP-4 expression up to 6× higher and significantly more osteoblasts in MM-prepared sites compared to rotary burs in the animal model. Clinical outcomes depend on case selection, technique, and protocol."
    },
    {
      "q": "How does it compare to rotary osseodensification (Densah / Versah)?",
      "a": "Rotary osseodensification reverses the cutting flute to laterally compact bone — same goal. Rotary osseodensification still involves rotation and thermal management. The Magnetic Mallet is non-rotary and avoids rotary friction heat during the osteotome phase. Both approaches are evidence-based; the technical principle differs and choice depends on case selection, clinician preference, and protocol."
    },
    {
      "q": "Are there peer-reviewed publications?",
      "a": "Yes. Bennardo 2022 systematic review (J Pers Med, MDPI, DOI 10.3390/jpm12010108) analyzed 14 studies covering 619 extractions and 880 implants. Schierano 2021 (Materials, MDPI, DOI 10.3390/ma14226945 — pilot animal study) and Baldi 2024 (Exploration of Medicine, DOI 10.37349/emed.2024.00232 — in-vitro porcine rib model) report significant advantages on accuracy, temperature, bone preservation, and osteogenesis in the respective study models. The Clinicians Report independent evaluation listed Magnetic Mallet among the most innovative products of the year."
    },
    {
      "q": "Are these studies clinical trials on humans?",
      "a": "Mixed designs. The Bennardo 2022 systematic review aggregates 14 studies including human clinical data (619 extractions / 880 implants). Schierano 2021 is a pilot animal study, not a human trial. Baldi 2024 is an in-vitro porcine rib study, not in-vivo. The body of evidence on the Magnetic Mallet includes peer-reviewed publications across in-vitro, animal, and human-clinical study designs; it is not equivalent to large randomized controlled trials."
    },
    {
      "q": "Can I use it in the mandible?",
      "a": "Yes — for extractions, split crest, apical root removal in proximity of the inferior alveolar nerve, and All-on-X angled accesses. In dense D1 mandibular bone, conventional rotary drilling typically remains the efficient choice for the principal preparation."
    },
    {
      "q": "Is there a learning curve?",
      "a": "Pen-style grip, single hand. Protocols are similar to rotary protocols."
    }
  ],
  "medical_disclaimer": "The Magnetic Mallet is a medical device for professional use, restricted to qualified dental professionals according to the instructions for use. ISO 13485. CE-marked. Manufactured by Meta Ergonomica S.r.l. (Italy). Clinical outcomes depend on case selection, surgical technique, and protocol; the information on this page is for educational purposes and does not replace the clinical judgment of the professional. Citations of pilot animal studies, in-vitro studies, and systematic reviews are reported with their respective study types and should not be interpreted as equivalent to large clinical trials on humans.",
  "locale": "en-IN",
  "country": "IN",
  "target_market": "India",
  "last_updated": "2026-09-15",
  "source": {
    "repository_commit": "3df61189cfaaa040bafadde2a2dad1be30a94705",
    "companion_path": "/en/data/magnetic-mallet.json",
    "source_sha256": "24e136be61b11c0bdaa3ff5f14263d87770c8d6ed9d41980fce9f327e003aaee",
    "adaptation": "Regional companion derived from the current English source; local commercial information replaces the source market blocks."
  },
  "india_services": {
    "contact": {
      "organisation": "OSSEOTOUCH India",
      "name": "OSSEOTOUCH Product Specialist in India",
      "role": "Product specialist",
      "phone": "+919810344461",
      "email": "osseotouchindia@gmail.com",
      "whatsapp": "https://wa.me/919810344461",
      "page": "/en-in/contact/"
    },
    "device_warranty_years": 2,
    "availability": {
      "stock_location": "India",
      "delivery": "Immediate delivery from stock in India; confirm the order details with the OSSEOTOUCH Product Specialist in India."
    },
    "programmes": [
      {
        "name": "Demo",
        "registration_required": true,
        "url": "/en-in/myosseotouch/?intent=demo"
      },
      {
        "name": "Pay as you use",
        "registration_required": true,
        "url": "/en-in/myosseotouch/?intent=pay-as-you-use"
      }
    ],
    "request_a_quotation": "Contact the OSSEOTOUCH Product Specialist in India to discuss the device, kit or configuration you need.",
    "after_sales": {
      "page": "/en-in/after-sales-service/",
      "request_to": "osseotouchindia@gmail.com",
      "request_cc": "contact@osseotouch.com",
      "first_response_hours": 24,
      "commitment": "Requests are taken in charge within 24 hours. This is an acknowledgement and case-handling commitment, not a promise that a repair is completed within 24 hours.",
      "request_details": "General request, problem description and, for device owners, serial number and a photo of the serial label or device.",
      "whatsapp": "https://wa.me/919810344461"
    }
  },
  "india_faq": [
    {
      "q": "How can I request a demo in India?",
      "a": "Register or sign in to MyOSSEOTOUCH and choose Demo.",
      "url": "/en-in/myosseotouch/?intent=demo"
    },
    {
      "q": "How can I request Pay as you use?",
      "a": "Register or sign in to MyOSSEOTOUCH and choose Pay as you use. Discuss the programme with the OSSEOTOUCH Product Specialist in India.",
      "url": "/en-in/myosseotouch/?intent=pay-as-you-use"
    },
    {
      "q": "Who supports the Magnetic Mallet in India?",
      "a": "The OSSEOTOUCH Product Specialist in India provides local product support. After-sales requests go to the OSSEOTOUCH Product Specialist in India, with a copy to contact@osseotouch.com, and are taken in charge within 24 hours.",
      "url": "/en-in/after-sales-service/"
    },
    {
      "q": "What warranty and availability are offered in India?",
      "a": "The Magnetic Mallet device has a 2-year warranty. Stock is held in India for immediate delivery. Contact the OSSEOTOUCH Product Specialist in India for the quotation and order details."
    }
  ],
  "documentation": {
    "manufacturer": "Meta Ergonomica S.r.l., Italy",
    "brand_owner": "OSNRGY SRL",
    "documentation_context": "International studies and European device documentation describe their original scope. They do not constitute a statement of regulatory approval for India. Obtain applicable device documentation from the local product specialist.",
    "use": "For qualified dental professionals; follow the instructions for use and the requirements applicable to the treatment setting."
  },
  "platform_facts": {
    "technology": "MAGNETODYNAMICS",
    "impulse_duration_microseconds": 50,
    "force_levels_daN": [
      75,
      90,
      130,
      260
    ],
    "maximum_force_daN": 260,
    "maximum_force_kgf_approx": 265,
    "scope": "Technical values of the Magnetic Mallet platform; compatible kits use the device according to their instructions for use."
  }
}