Black Ruby DLC-coated instruments for osteotomy and bone-condensation protocols. Discover more → OSSEOTOUCH India · Magnetic Mallet System
First Lancet Osteotome
One osteotome, no pilot drill
Lancet Osteotome by Prof. Domenico Baldi · Ø 1.8 mm · 4-faced tip · alternative to the rotary pilot drill
A lancet osteotome designed by Prof. Domenico Baldi for use with MAGNETODYNAMICS as an alternative to the rotary pilot drill. The 4-faced sharp tip (Ø 1.8 mm) penetrates the cortical plate through lateral expansion and bone condensation — non-rotary, rotary bur-free, no routine irrigation required during preparation. Particularly relevant for thin-ridge implant placement, post-extractive socket axis correction, and flapless implant placement workflows.
Pilot drill alternative·Lancet osteotome·Ø 1.8 mm 4-faced tip·Rotary bur-free·Flapless implant placement·Thin ridge·Post-extractive·Prof. Baldi·Pilot drill alternative
Let’s make this useful to you · FIRST
What would you like to understand?
Start with a question. Explore the details here, or ask our team about the part that matters to you.
No appointment needed to ask.Talk with OSSEOTOUCH Product Specialist in India, your product contact in India.
WhatsApp OSSEOTOUCH IndiaWhat does this include?
See the instruments and their descriptions together, before comparing configurations or asking about a particular component.
How is it used?
Start with the original demonstration or protocol on this page. Then ask us about the instrument or step you would like explained.
Where would I start?
You do not need to decide on a configuration yet. Tell us which procedures you want to explore and what you already know about Magnetic Mallet.
01 The clinical problem
The pilot drill subtracts bone
where you can't afford to lose it
The conventional implant protocol begins with the pilot drill — a rotating instrument that removes bone to create the initial osteotomy. Removing bone weakens the implant site, generates frictional heat, and requires continuous irrigation. On thin ridges, the drill can skid on the cortical plate, axis control is compromised, and a millimeter error reshapes the entire implant trajectory. In post-extractive sockets, the irregular geometry of the residual walls makes axis determination with a rotary drill even harder.
02 The First approach
A lancet osteotome
that condenses, doesn't drill
First is a lancet osteotome with a 4-faced sharp tip (Ø 1.8 mm) designed by Prof. Domenico Baldi. Coupled to the Magnetic Mallet, it penetrates the cortical plate through lateral expansion and bone condensation — non-rotary, rotary bur-free, no routine irrigation required during preparation. The 4 sharp faces engage the cortical without skidding, even on knife-edge ridges. In post-extractive sockets, First redefines the socket axis before implant osteotomy.
Your next step, in India
Try it. Learn it. Make it part of your practice.
Request a demo or explore Pay as you use through your MyOSSEOTOUCH account.
02 First in action
Watch it at work
animation + designer's explanation
Two videos to understand the lancet osteotome — usage walkthrough and the designer's clinical rationale.
03 Six benefits
Six benefits
of cortical entry using MAGNETODYNAMICS
One instrument. Six reasons the first step of the implant protocol becomes more bone-preserving and more axis-controlled than rotary pilot drilling.
Pilot-drill-free workflow
Eliminates the rotary pilot drill from the implant protocol. The lancet tip penetrates the cortical plate without removal — only expansion and condensation.
Axis control on thin ridges
4 sharp faces engage the cortical without skidding. Stays on the planned axis even on knife-edge ridges where rotary drills tend to deflect.
Bone condensation
Compacts cortical bone during penetration instead of removing it. Higher peri-implant bone density commonly supports primary stability.
Avoids rotary friction heat
Non-rotary advancement avoids the rotary friction heat conventional pilot drilling generates. No routine irrigation required during this phase.
Axis correction in real-time
If the trajectory needs adjustment during the preparation, the same instrument can redirect — no additional drill changes required.
Single-instrument addition
Adds to any Magnetic Mallet kit or purchased standalone. No additional handpiece required — works with the new-generation Magnetic Mallet you already have.
Bring the lancet osteotome
to your implant protocol
Talk with our specialist to evaluate First for your implant workflow, check compatibility with your existing Magnetic Mallet handpiece, or ask a product question.
Speak with the OSSEOTOUCH Product Specialist in India. For after-sales support, requests are taken in charge within 24 hours.
04 Technical specifications
One instrument
one purpose
First is a single lancet osteotome designed for use with MAGNETODYNAMICS. Compatible with the Magnetic Mallet handpiece you already use.
Specifications
| Spec | Value |
|---|---|
| Designer | Prof. Domenico Baldi (University of Genoa) |
| Tip shape | Lancet — 4 sharp faces |
| Diameter | Ø 1.8 mm |
| Material | Surgical-grade stainless steel |
| Sterilization | Autoclavable, standard protocols |
| Compatibility | New-generation Magnetic Mallet handpieces (all kits) |
| Purchase options | Standalone or add-on to any Magnetic Mallet kit |
Working principle: the Magnetic Mallet handpiece delivers 50-microsecond impulses to the lancet tip. The 4 sharp faces engage the cortical plate without skidding; the bone is laterally expanded and compacted rather than rotated and removed. No routine irrigation required during the preparation phase.
OSSEOTOUCH INDIA
Explore the right instruments for your practice. Talk with our team in India.
Local stock · 2-year device warranty · Product guidance from OSSEOTOUCH Product Specialist in India
05 Clinical applications
Four clinical applications
one cortical entry workflow
First covers the implant scenarios where rotary pilot drilling is most likely to compromise axis control, primary stability, or workflow simplicity.
Thin / knife-edge ridges
The 4-faced lancet tip engages the cortical plate without skidding, where conventional pilot drills tend to lose axis control. Atraumatic cortical penetration with controlled lateral expansion.
Post-extractive immediate implant
Redefines the axis of the residual extraction socket before implant osteotomy. Corrects the geometric irregularities of the socket walls that make axis determination with a rotary drill difficult.
Flapless implant placement
Replaces the rotary pilot drill in flapless mini-invasive workflows where soft-tissue management constrains irrigation and visibility. Non-rotary advancement avoids rotary friction heat at the cortical entry.
Dense cortical bone access
Penetrates well-mineralized cortical without rotary friction heat. Supports an approach that aims to preserve cortical bone integrity at the implant entry point.
OSSEOTOUCH INDIA
Explore the right instruments for your practice. Talk with our team in India.
Local stock · 2-year device warranty · Product guidance from OSSEOTOUCH Product Specialist in India
06 Frequently asked questions
Common questions
about First
What is First and what is it used for?
First is a lancet osteotome designed by Prof. Domenico Baldi for use with MAGNETODYNAMICS as an alternative to the rotary pilot drill in implant site preparation. The 4-faced sharp tip (Ø 1.8 mm) penetrates the cortical plate through lateral expansion and bone condensation — non-rotary, rotary bur-free, no routine irrigation required during the preparation phase. Particularly suited to thin ridges, post-extractive sockets, and flapless implant placement workflows.
Do I need the Magnetic Mallet to use First?
Yes. First is designed for the OSSEOTOUCH Magnetic Mallet handpiece. It connects to the handpiece like any other instrument in the range. If you already own a Magnetic Mallet, First can be added as a standalone instrument or to any existing kit.
How is First different from a conventional pilot drill?
A conventional pilot drill rotates and removes bone to create the initial osteotomy. First does not rotate and is designed to preserve bone by lateral expansion and condensation rather than rotary removal. The result: no rotary friction heat during preparation, no routine irrigation required, denser bone at the cortical entry, and better axis control on thin or irregular ridges.
Can First be used on very thin ridges?
Yes — this is one of the primary indications. The 4-faced lancet tip does not skid even on knife-edge ridges, allowing the surgeon to maintain the planned axis where conventional rotary pilot drills tend to deflect.
Can First be used in post-extractive sockets?
Yes — particularly indicated for this scenario. First redefines the axis of the residual extraction socket before implant osteotomy, correcting the geometric irregularities that make axis determination with a rotary pilot drill difficult.
Is First a good fit for flapless implant placement?
Yes. Flapless workflows constrain soft-tissue management and irrigation access at the cortical entry point. First's non-rotary advancement avoids the rotary friction heat that conventional pilot drilling generates — a recognized concern in flapless protocols where irrigation cooling is most constrained.
Can First be added to an existing Magnetic Mallet kit?
Yes. First can be added to any Magnetic Mallet kit or purchased as a standalone instrument. No additional handpiece required — works with the new-generation Magnetic Mallet you already have.
How can I get product documentation and support in India?
Contact OSSEOTOUCH Product Specialist in India, for documentation, compatibility questions and a quotation. The Magnetic Mallet device has a 2-year warranty. For after-sales requests, use the service page or contact OSSEOTOUCH Product Specialist in India on WhatsApp.
OSSEOTOUCH INDIA
Explore the right instruments for your practice. Talk with our team in India.
Local stock · 2-year device warranty · Product guidance from OSSEOTOUCH Product Specialist in India
Ready to get started?
Talk with our team — we'll help you evaluate First for your implant workflow and clarify your questions about the instruments.
Talk to OSSEOTOUCH Product Specialist in India
Contact OSSEOTOUCH Product Specialist in India, to discuss your workflow.
Email our specialists
osseotouchindia@gmail.com
Direct chat with our team.
First is part of the OSSEOTOUCH Magnetic Mallet system, manufactured by Meta Ergonomica S.r.l. (Italy). ISO 13485. Use restricted to qualified dental professionals according to the instructions for use.
Evidence on this technique
Peer-reviewed research on surgery based on MAGNETODYNAMICS. The studies concern the technique, not this single instrument.
- Influence of implant site preparation method on three characteristics: magnetodynamic mallet versus conventional drill
- Effect of implant macro-design and magnetodynamic surgical preparation on primary implant stability: an in-vitro investigation
- Biomolecular, Histological, Clinical, and Radiological Analyses of Dental Implant Bone Sites Prepared Using Magnetic Mallet Technology: A Pilot Study in Animals